详情
产品规格 图文详情
名称:
MPPT 30T
产品用途:
太阳能

Sun YoBa MPPT-30T太阳能控制器 双时控30A太阳能专用控制器T30多用途太阳能充放电控制器

产品介绍:

MPPT30控制器是一种智能型,多用途太阳能充放电控制器。该系列产品使用订制的LCD显示屏,具有非常友好的操作界面;各控制参数可灵活设定,充分满足您的不同需求。

MPPT30具有如下特点:

1.MPPT功能:本控制器特点在于智能调节太阳能发电板的工作电压能跟踪太阳能板发出最大电流,使太阳能板始终工作在V-A特性曲线的最大功率点。比较普通太阳能控制器,对太阳能板发电功率的利用提高了10-30%;

2.形象的LCD图形符号,简洁的按键模式;

3.带自动温度补偿的智能型PWM充电方式;

4.可调节的从放电控制参数,可设置的负载工作模式;

5.蓄电池反向放电,欠压,反接保护等各种保护功能。

产品编码: T30

申报品名: solar controller

净重: 0.390KG

重量: 0.440KG

尺寸: 20.50*6.50*10.50CM




一:Product introduction

Solar LCD series a kind of intelligent, multi-purpose solar charge and discharge controller

LCD screen display

Battery reverse discharge protection

Easy operation interface

Battery reverse polarity protection

MPPT+ PWM charging mode

Battery under voltage protection

Parameter user can reset

Overload, short-circuit protection

A key to open and close the load

Automatic temperature compensation function

A key to restore the factory settings

USB 5V charging (for 500mA) for mobile phone


二: Installation Instructions

Installation

① Ready Qi installation tools and materials, and cable. Please matching suitable cable

② Ensure that the current density <4A/mm2 this will help to reduce the line pressure drop.

Recommended: 30A current 10mm2  Check whether the installation site,Comply with the relevant safety requirements, avoid 

  damp, dusty, there is easy

Inflammable, explosive and corrosive gases place to install using the controller

③ Install the controller fixed to the vertical plane, see Section V mounting aperture and hole spacing. In order to ensure a good controller cooling conditions, the controller on the bottom of each reserved 10cm space


④ As shown on the right wiring sequence: load, battery, solar

Battery plate is connected to the controller to be taken to ensure that the load, battery,

The polarity of the solar cell panel and controller

⑤ Before use: external temperature sensor probe into the left of the controller temperature probe interface probe placed in similar battery temperature. (Line extension must be built-in devices of the external temperature probe coextensive Otherwise, the controller will control parameters of the temperature compensation of the error

⑥ Warning: In order to prevent accidents from occurring, install: non-professionals can not be engaged in loading and unloading operations

三LCD operating interface deion

1:LCD graphic symbol deion



LOAD ON 1 H---23H      Load control (1 hour --- 23 hours can be set)

LOAD ON 24H    24 hour -is normally open state

0h-light control mode, power supply load after dark, closed after daybreak the load

24h-represents a normal mode, in the case of no fault, the load is always in the power supply state.

1h ~ 23h-light control delay mode, after dark began to power the load, and delay to set the time to close the load.

  Charging current

 Discharge current

 Voltage charging station (can be set)

Undervoltage protection voltage (can be set

 Temperature display (around the probe)

 Undervoltage recovery voltage (can be set

2  Function keys:

: Toggle key

+”Set parameters: "plus"

-” Set parameters: "Minus"

 Manual switch load

   Long press and hold this button for 5 seconds to restore the factory settings

  "×" error or system failure, click this button, you can troubleshoot or eliminate "x"

3 Parameter settings (≥ 5 seconds keystrokes, parameters are saved automatically)

:PV OFF:88.8VLOAD ON:24HLOAD OFF:88.8VLOAD ON:88.8VSet order (automatic cycle) 

+ Parameters "+" setting  

- Parameters "-" setting

This button can be "manually" open load or manually close the load.

Long press and hold this button for 5 seconds to restore the factory settings

"×" error or system failure, click this button, you can troubleshoot or eliminate "x"


四   Common fault with processing methods

Battery under-voltage protection

Battery normal power supply



a)   Undervoltage protection and handling: screen display as shown on the right indicates the battery voltage is below the undervoltage protection voltage, the controller has entered undervoltage

b) Retaining state, disconnect the load circuit. Using solar panels or charger to charge the battery when the accumulator

c) After the battery voltage reaches the undervoltage recovery voltage, the controller will restore power to the load, into normal working condition

1) Overload protection and processing methods:

The screen shown at right load circuit current is greater than the rated current or load short-circuit, overload state controller has entered. Reduce the load troubleshooting, press the button, restore power to the load

 System fault

o r  Fault has ruled out

2) To charging failure handling method

a) Solar energy to battery charging, if there is no correct configuration solar panels of power or exceed rated charging current, voltage, will appear charge fault, the checking and debugging, press the button, recoverability work.k

Charge fault

 Fault has ruled out

3) Solar panels fault and processing:

a) 24 hours in the case of sun light, the controller is not charging, the solar energy is not connected or not connected correctly, check the solar panel to the connecting cable of the controller is open, troubleshooting, recoverability work. 

 No solar charge

Are charging

五 Parameter table

       model

Parameters

MPPTM 30

model

Parameters          

MPPT 30

Rated working current

30A

Installation wire number 

7#  AWG  (10mm2)

Rated working voltage

12V/24V

Working temperature

-10~60

Solar panels voltage

48V

Storage temperature

-30~70

Float charging voltage(settable)

13.8V/27.6V

Humidity requirements

≤90,NO GEL 

Low voltage protection(settable)

10.7V/21.4V

dimension

90 mm×188 mm×48 mm

Low voltage recovery(settable)

12.5V/25.0V

Mounting hole spacing

60 mm×178 mm --Φ5

No-load loss

15mA

weight

460g

Loop pressure drop

160mV

Temperature compensation

-4mV/Cell/

Charging mode

MPPT+PWM mode